Retinal Ganglion Cell Responses to Low-frequency Focused Ultrasound Stimulation
Huixia Zhao; Qiuju Jiang; Guofeng Li; Weibao Qiu
2017-07
会议名称2017年第二届曲阜视觉科学会议
会议日期2017.7.1
会议地点曲阜
摘要

PURPOSE: Acoustic retinal prosthesis has been put forward using high-frequency US with non-invasive and high-resolution advantages. But its application is limited by the difficulties in fabrication, energy consumption and acoustic attenuation. In the present study, low-frequency focused ultrasound stimulation (LFUS) had been demonstrated to activate retinal ganglion cells (RGCs) in rat retinas. The neurophysiological properties of RGC responses to LFUS were also investigated.
METHODS: A 2.25 MHz focused ultrasound transducer (D=0.75 in., SF=2.0 in.) was used to stimulate the rat retina which was cultured in a multi-electrode array system (MEA2100, MCS , Fig. 1). The acoustic property was evaluated by hydrophone (UMS3, Precision acoustics). Ultrasound (US) stimulation was modulated at pulsed mode. Light stimulation was modulated in the same mode to give an uniform field flashes. The electrophysiological data collected from MEA was detected for neural spikes and sorted by Plexon Offline Sorter. Only channels recording single-cell activities were adopted for subsequent analysis. Peri-stimulus time histograms and raster plots were plotted for each RGC using Spike 2.
RESULTS: In total, 116 retinal ganglion cells (RGCs) from 7 retinas were sorted and classified into four types according to light responses. The firing activity of 114 RGCs were modulated by repeated US stimulation. This suggested that low-frequency focused ultrasound stimulation (LFUS) could activate RGCs. The US responses didn’t correspond to the standard light responses and varied greatly between cell types. Besides, dual-peak responses to US stimulation were observed which were not reported previously. The temporal response properties of RGCs, including latency, firing rate, and response type, could be modulated by changing acoustic intensity.
CONCLUSIONS: These findings might imply a temporal neuromodulation effect of LFUS and provided an important foundation for the development of acoustic retinal prosthesis.

关键词retinal ganglion cell ultrasound stimulation acoustic retinal prosthesis
学科领域视觉神经科学
语种英语
文献类型会议论文
条目标识符http://ir.psych.ac.cn/handle/311026/22053
专题心理所主办、承办、协办学术会议_2017年第二届曲阜视觉科学会议_会议摘要
作者单位Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences
推荐引用方式
GB/T 7714
Huixia Zhao,Qiuju Jiang,Guofeng Li,et al. Retinal Ganglion Cell Responses to Low-frequency Focused Ultrasound Stimulation[C],2017.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Huixia Zhao]的文章
[Qiuju Jiang]的文章
[Guofeng Li]的文章
百度学术
百度学术中相似的文章
[Huixia Zhao]的文章
[Qiuju Jiang]的文章
[Guofeng Li]的文章
必应学术
必应学术中相似的文章
[Huixia Zhao]的文章
[Qiuju Jiang]的文章
[Guofeng Li]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。